No Preview Available ! Data Sheet, Rev. 1.4, October 2014
TLE8209-2
SPI Programmable H-Bridge
Automotive Power
1 page TLE8209-2
Pin Configuration
2.2 Pin Definitions and Functions
Pin Symbol Function in SPI Mode
Function in Status Flag Mode
1 GND
Ground
Ground
2 SO
SPI Serial Data Out
no function - connect to GND
3 VDDIO Supply Voltage for Logic Output Buffer
Switches to SF-mode if connected to GND
4 SS/SF Slave Select (low active)
Status Flag (low active)
5 CP
Pin for external Charge Pump Capacitor
Pin for external Charge Pump Capacitor
6 VS
Battery Supply Voltage, has to be connected to Battery Supply Voltage, has to be
pin 15
connected to pin 15
7 IN1
Input 1
Input 1
8 OUT1 Output 1
Output 1
9 DIS
Disable
Disable
10 GND
Ground
Ground
11 GND
Ground
Ground
12 ABE
Bidirectional Enable Pin
Bidirectional Enable Pin
13 OUT2
Output 2
Output 2
14 IN2
Input 2
Input 2
15 VS
Input battery supply voltage, has to be
connected to pin 6
Input battery supply voltage, has to be
connected to pin 6
16 SI
SPI Serial Data Input
no function - connect to GND
17 SCK
SPI Clock
no function - connect to GND
18 VDD
VDD supply
19 GNDABE Sense ground for VDD monitoring
20 GND
Ground
VDD supply
Sense ground for VDD monitoring
Ground
21 GND
Heatslug - connect to GND
Heatslug - connect to GND
Data Sheet
5 Rev. 1.4, 2014-10-28
5 Page TLE8209-2
Power Supply
CONFIG0=’0’: ABE is inactive after VDD returned to normal operating voltage and filtering time has expired.
At the transition from overvoltage to normal condition, the output stages will return to normal operation. For output
control via SPI the bits MUX and SINx in the config register have to be re-programmed. New failures are not stored
to diagnostic registers during overvoltage, register content remains valid, writing new information to configure
registers is possible as far as they are not reset by ABE.
VDD Monitoring Test Mode
Testing of VDD monitoring is possible in SPI mode only. The latch function for over voltage at VDD has to be
switched of (CONFIG0=0 in STATCON_REG)
Testing upper threshold:
By writing 00xxxxxxb into STATCON_REG, the overvoltage threshold is reduced to VDD_TEST_H.
STATCON_REG bit 2 and 0 have to be LOW then. After writing 1xxxxxxxb to STATCON_REG, bit 2 and 0 in
STATCON_REG must be HIGH again
Testing lower threshold:
By writing 01xxxxxxb into STATCON_REG, the undervoltage threshold is increased to VDD_TEST_L.
STATCON_REG bit 2 and 1 have to be LOW then. After writing 1xxxxxxxb to STATCON_REG, bit 2 and 1 in
STATCON_REG must be HIGH again.
5.3 VDDIO - Digital Output Supply and Diagnostic Mode Selection
The voltage at VDDIO is used to supply the output buffer at the SO pin (serial output of SPI-interface). The VDDIO
pin is also used to select SPI- or in status flag (SF) diagnostic mode. As soon as VDDIO is lower than VDDIO_L, the
device is put into status flag mode.
.
to internal logic
(SF-mode / SPI-mode)
+
- SF/SPI - mode
threshold VDDIO_L
VDDIO
from internal logic
SO
Figure 5 VDDIO and SO-Pin
Data Sheet
11
Rev. 1.4, 2014-10-28
11 Page |
Páginas | Total 30 Páginas | |
PDF Descargar | [ Datasheet TLE8209-2.PDF ] |
Número de pieza | Descripción | Fabricantes |
TLE8209-2 | SPI Programmable H-Bridge | Infineon Technologies |
TLE8209-2SA | SPI Programmable H-Bridge | Infineon Technologies |
TLE8209-4SA | SPI Programmable H-Bridge | Infineon Technologies |
Número de pieza | Descripción | Fabricantes |
SLA6805M | High Voltage 3 phase Motor Driver IC. |
Sanken |
SDC1742 | 12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters. |
Analog Devices |
DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares, |
DataSheet.es | 2020 | Privacy Policy | Contacto | Buscar |