No Preview Available ! TM133XG-A02-03 Hoja de datos, Descripción, Manual


1 page




TM133XG-A02-03 pdf
[Note 6] Measurement points
1/6Hp 1/2Hp 5/6Hp
1/6Vp
1/2Vp
5/6Vp
12
3
45
Active area
Vp: Total Number of Vertical pixel
Hp: Total Number of horizontal pixel
[Note 7] Measurement condition
(1) Measurement equipment: BM-5A (TOPCON Corp.), Field=2 degree
(2) Ambient temperature Ta: 25 +/- 2 degC
(3) LCD: All pixels are WHITE, VDD=3.3V, fV=60Hz
(4) Measure after 30 minutes of CFL warm up.
(5) IL=(6.0) mArms with the Lamp inverter CXA-L0612A-VJL (TDK).
BACKLIGHT CHARACTERISTICS
ITEM
Lamp voltage
Lamp current
Operating
frequency
Start up voltage
Lamp life time
SYM. CONDITIONS MIN
VL -
IL TBD
fL TBD
VS -
tOL TBD
TYP
TBD
-
-
-
-
MAX
-
TBD
TBD
TBD
-
UNIT
Vrms
mArms
kHz
Vrms
hrs
Ta=25 degC
NOTE
at IL=TBDmArms
(Recommended value)
(Recommended value)
at Ta=0 degC
at IL=TBD mArms
[Note 1] Backlight driving conditions (operating frequency fL especially) may interfere with
horizontal frequency fH, causing the beat or flicker on the display.
Therefore the operating frequency fL shall be adjusted in relation to horizontal
frequency fH to avoid interference.
[Note 2] The inverter open voltage should be larger than start up voltage, otherwise backlight
may blinking for a moment after turns on or not be turned on.
And this voltage should be applied to lamp for more than 1 second to start up,
otherwise backlight may not be turned on.
[Note 3] If driving current waveform is asymmetrical, mercury deviation inside of CFL will
incline to one side and consequently abnormal lighting may occur.
To prevent such unfavorable lighting, driving current waveform is asked to have
unbalance rate of less than 10% and wave-height rate of less than 2 +/- 10%.
And this driving waveform shall be confirmed in your system.
Unbalance rate = | Ip - I-p | / IL x 100 (%)
Ip Wave-height rate = Ip (or I-p) / IL
I-p
Current waveform
Ip : High peak value
I-p : Low peak value
IL : Effective value
[Note 4] The inverter of ground reference type should be used. The inverter of ground floating
type should not be used.
SANYO Electric Co., Ltd.
TM133XG-A02-03 Ver.1 Page 4/15

5 Page





TM133XG-A02-03 arduino
POWER ON/OFF SEQUENCE REQUIREMENT
VDD
Power-on
3.0V
0.3V
0V
0 < t1 < (25)ms
0 < t2 < (65)ms
LVDS input
0V
Lamp
(Recommend)
(100)ms < t6
ON
OFF
Power-off
(5)ms < t3 < (200)ms
3.0V
0.3V
0 < t4 < (50)ms
VALID DATA
VTH
VTL
VCM
(150)ms < t5
(0)ms < t7
When the power is off, LVDS input must be kept at either low level or high
impedance.
Power sequence for Lamp(backlight) is not specified especially, however it is
recommended to consider some timing difference between LVDS input as shown
above.
If backlight lights on before LCD starts function, or if backlight is kept on after LCD
stopped function, screen may look white for a moment or abnormal image may be
displayed.
This is caused by variation in output signal from timing generator at LVDS input on or
off. It does not cause damage to liquid crystal molecule and driving circuit.
SANYO Electric Co., Ltd.
TM133XG-A02-03 Ver.1 Page 10/15

11 Page







PáginasTotal 16 Páginas
PDF Descargar[ Datasheet TM133XG-A02-03.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
TM133XG-A02-03TFT Color LCD ModuleSanyo
Sanyo

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar