Absolute Maximum Ratings
T460HW08 V0 Product Specification
Rev. 1
The followings are maximum values which, if exceeded, may cause faulty operation or damage to the unit
Item
Logic/LCD Drive Voltage
Input Voltage of Signal
BLU Input Voltage
BLU on/off Control Voltage
BLU Brightness Control Voltage
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Panel Surface Temperature
Symbol
Vcc
Vin
VDDB
VBLON
Vdim
TOP
HOP
TST
HST
PST
Min
-0.3
-0.3
-0.3
-0.3
-0.3
0
10
-20
10
-
Max
14
4
28
7
7
+50
90
+60
90
65
Unit
[Volt]
[Volt]
VDC
VDC
VDC
[oC]
[%RH]
[oC]
[%RH]
[oC]
Conditions
Note 1
Note 1
Note 1
Note 1
Note 1
Note 2
Note 2
Note 2
Note 2
Note 3
Note 1: Duration:50 msec.
Note 2 : Maximum Wet-Bulb should be 39 and No condensation.
The relative humidity must not exceed 90% non-condensing at temperatures of 40 or less. At temperatures
℃ ℃greater than 40 , the wet bulb temperature must not exceed 39 .
Note 3: Surface temperature is measured at 50 Dry condition
Copyright AUO Optronics Corp. 2009 All Rights Reserved.
Page 5 / 30

5 Page





T460HW08-V0 arduino
3.3 Signal Timing Specification
T460HW08 V0 Product Specification
Rev. 1
This is the signal timing required at the input of the user connector. All of the interface signal timing should be
satisfied with the following specifications for its proper operation.
Signal
Item
Symbol
Min. Typ. Max Unit
Vertical Section
Period
Active
Tv
Tdisp (v)
1090
1125
1080
1480
Th
Th
Blanking
Tblk (v)
10 45 400 Th
Period
Th
1030
1100
1325
Tclk
Horizontal Section
Active
Tdisp (h)
960 Tclk
Blanking
Tblk (h)
70 140 365 Tclk
Clock
Frequency
Fclk=1/Tclk
50
74.25
82 MHz
Vertical Frequency
Frequency
Fv
47 60 63 Hz
Horizontal Frequency
Frequency
Fh
60 67.5 73 KHz
Notes:
(1) Display position is specific by the rise of DE signal only.
Horizontal display position is specified by the rising edge of 1st DCLK after the rise of 1st DE, is displayed on the
left edge of the screen.
(2) Vertical display position is specified by the rise of DE after a “Low” level period equivalent to eight times of
horizontal period. The 1st data corresponding to one horizontal line after the rise of 1st DE is displayed at the top
line of screen.
(3) If a period of DE “High” is less than 1920 DCLK or less than 1080 lines, the rest of the screen displays black.
(4) The display position does not fit to the screen if a period of DE “High” and the effective data period do not
synchronize with each other.
Copyright AUO Optronics Corp. 2009 All Rights Reserved.
Page 11 / 30

11 Page







PáginasTotal 30 Páginas
PDF Descargar[ Datasheet T460HW08-V0.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
T460HW08-V0LCD ModuleAUO
AUO
T460HW08-V2TFT LCD MODULEAUO
AUO
T460HW08-V3LCD ModuleAUO
AUO
T460HW08-V5LCD ModuleAUO
AUO

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar