DataSheet.es    


PDF ISC300 Data sheet ( Hoja de datos )

Número de pieza ISC300
Descripción Universal Precision Isolated MEASUREMENT CHANNEL
Fabricantes Burr-Brown Corporation 
Logotipo Burr-Brown Corporation Logotipo



Hay una vista previa y un enlace de descarga de ISC300 (archivo pdf) en la parte inferior de esta página.


Total 11 Páginas

No Preview Available ! ISC300 Hoja de datos, Descripción, Manual

® ISC300
www.DataSheet4U.com
Universal Precision Isolated
MEASUREMENT CHANNEL
FEATURES
q CALIBRATION CAPABILITY
q INTEGRAL SENSOR EXCITATION
q OPEN CIRCUIT SENSOR DETECTION
q LOW POWER: 80mW
q INSTRUMENT AMPLIFIER INPUT
q PROGRAMMABLE GAIN
q 12-BIT LINEARITY
q TWO ISOLATED POWER SUPPLIES:
±13V at 5mA
q LOW DRIFT 10V REFERENCE
APPLICATIONS
q UNIVERSAL INPUT CHANNEL FOR
PROCESS CONTROL SYSTEMS
q ISOLATED MEASUREMENT CHANNEL
FOR THERMOCOUPLE, RTD AND
VOLTAGE TRANSDUCERS
q CHANNEL TO CHANNEL ISOLATED
MULTIPLEXED SYSTEMS
q ISOLATED 4 TO 20mA RECEIVER
DESCRIPTION
The ISC300 is an isolated measurement channel with
open circuit sensor detection for use with RTD and
thermocouple temperature sensors. In addition to tem-
perature measurement, the ISC300 can accept full
scale input voltages of ±100mV and ±10V which
allows use with other sensors such as pressure, humid-
ity and flow sensors. The low level resistance mea-
surement capability also allows stimulus and measure-
9 +VISO
2 –VISO
8 Sense 2
5 +IP
6 –IP
3 Sense 1
1 VREF
4 IREF1
7 IREF2
10 Com 1
20M
+VISO
Filter
Channel 1 Out
20M
–VISO
Ref
10.0V
MUX
Channel 2
99R
0.100V
Channel 3
Current
Reference
–VISO
R
Com 1
Channel 4
A1 A0
PGA
Input Side
ment of strain gauges. The measurement channel has
a highly stable internal reference which can be se-
lected from the output side. This allows the user to
calibrate each channel at the factory, record the cali-
bration data and periodically recalibrate the system
while in use over time and ambient temperature
changes.
Barrier
Modulate
Demod
Rectify
Power
Com 1
O
P
T
O
Com 2
C
O
U
P
L
E
L
A
T
C
H
Output Side
INPUT
SELECT A1
A0
Com1
+0.1V
Out 28 +10V
Signal
00
01
10
11
VCC (+15) 25
CKI
Com 2
26
27
VDD (+5) 18
CLK 22
G 19
A0 20
A1 21
RST
23
DCom 2 24
GAIN
SELECT
0.5
50
G
0
1
SELECT
and GAIN
No Change
No Change
Latch
RESET
RST CLK
10
11
1^
0X
International Airport Industrial Park • Mailing Address: PO Box 11400 • Tucson, AZ 85734 • Street Address: 6730 S. Tucson Blvd. • Tucson, AZ 85706
Tel: (520) 746-1111 • Twx: 910-952-1111 • Cable: BBRCORP • Telex: 066-6491 • FAX: (520) 889-1510 • Immediate Product Info: (800) 548-6132
©1991 Burr-Brown Corporation
PDS-1135A
Printed in U.S.A. October, 1993

1 page




ISC300 pdf
PGA
The programmable gain amplifier allows the user to digitally
select device gains of 0.5 and 50, allowing input ranges of
±0.1V or, ±10V full scale. When used in conjunction with
the 0.1V, 10V and common references, channel calibration
can be performed.
Isolated Supplies
Two 13V isolated supplies, capable of supplying 5mA each,
are available to power signal conditioning circuitry.
OUTPUT SECTION
The output section passes power across the isolation barrier
to provide the isolated supplies, and demodulates the signal
www.DataSheet4U.comtransmitted back across the isolation barrier.
ABOUT THE BARRIER
For any isolation product, barrier integrity is of paramount
importance in achieving high reliability. The ISC300 uses
miniature transformers designed to give maximum isolation
performance when encapsulated in a high dielectric strength
material. The device is designed so that the barrier is located
at the center of the package.
HIGH VOLTAGE TESTING
Burr-Brown Corporation has adopted a partial discharge test
criterion that conforms to the German VDE0884 Opto-
coupler Standards. This method requires the measurement of
minute current pulses (< 5pC) while applying 800Vrms,
60Hz high-voltage stress across every device isolation
barrier. During a two second test partial discharge must
occur five times on five separate half cycles of 60Hz,
and each time occurrence must not be separated by a line
period of more than four half cycles in order to produce a
partial discharge fail. This confirms transient overvoltage
(1.6 x Vrated) protection without damage. Life-test results
verify the absence of failure under continuous rated voltage
and maximum temperature.
This new test method represents the “state-of-the-art” for
nondestructive high voltage reliability testing. It is based on
the effects of non-uniform fields existing in heterogeneous
dielectric material during barrier degradation. In the case of
void non-uniformities, electric field stress begins to ionize
the void region before bridging the entire high voltage
barrier.
The transient conduction of charge during and after the
ionization can be detected externally as a burst of 0.01µs –
0.1µs current pulses that repeat on each AC voltage cycle.
The minimum AC barrier voltage that initiates partial dis-
charge is defined as the “inception voltage.” Decreasing the
barrier voltage to a lower level is required before partial
discharge ceases and is defined as the “extinction voltage.”
We have designed and characterized the package to yield an
inception voltage in excess of 800Vrms so that transient
overvoltages below this level will not cause any damage.
The extinction voltage is above 500Vrms so that even
overvoltage-induced partial discharge will cease once the
barrier voltage is reduced to the rated level. Older high
voltage test methods relied on applying a large enough
overvoltage (above rating) to catastrophically break down
marginal parts, but not so high as to damage good ones. Our
new partial discharge testing gives us more confidence in
barrier reliability than breakdown/no breakdown criteria.
BASIC OPERATION
SIGNAL AND SUPPLY CONNECTIONS
As with any mixed signal analog and digital signal compo-
nent, correct decoupling and signal routing precautions must
be observed to optimize performance. The ISC300 has an
internal 0.1µF decoupling capacitor at VCC, so additional
VCC decoupling will not be necessary. However, a ground
plane will minimize potential noise problems. If a low
impedance ground plane is not used, Com 2 should be tied
directly to the ground at the supply. It is not necessary to
connect DCom 2 and Com 2 at the device. Layout practices
associated with isolation signal conditioners are very impor-
tant. The capacitance associated with the barrier and series
resistance in the signal and reference leads must be mini-
mized. Any capacitance across the barrier will increase AC
leakage, and in conjunction with ground line resistance, may
degrade high frequency IMR, see Figure 2.
INPUT CONFIGURATION
The ISC300 allows easy configuration for temperature mea-
surement using an RTD. Figure 3 shows the basic connec-
tions for RTD operation. The two reference currents excite
the resistance transducer and a current-to-voltage conver-
sion is made corresponding to the resistance value of the
transducer. If a gain of 50 is selected, a 10resistance value
results in a (10 • 200µA) • 50 = 0.1V output; the 500full
scale value gives a (500 • 200µA) • 50 = 5V output. The
connection of the sense line allows open circuit sensor
detection. An open circuit will give a corresponding > 5.1V
output. A short circuit will give a corresponding < 0.1V
output. See the Applications section under Fault Conditions
for more information.
Com 1
CINT
Com 2
CEXT
VISO
R
FIGURE 2. Barrier Capacitance.
®
5 ISC300

5 Page





ISC300 arduino
www.DataSheet4U.com
+VSS1
INA102
–VSS1
+VSS1 –VSS1
IREF2
+In
–In
IREF1
Com 1
+VCC
Out
ACom 2
+VDD
DCom 2
Logic
Control
FIGURE 18. Temperature Measurement Using Thermocouple with Small Span.
+VSS1
INA102
4990
30
100–VSS1
+VSS1 –VSS1
IREF2
+In
–In
IREF1
Com 1
+VCC
Out
ACom 2
+VDD
DCom 2
Logic
Control
FIGURE 19. Thermocouple with Cold Junction Compensation.
The information provided herein is believed to be reliable; however, BURR-BROWN assumes no responsibility for inaccuracies or omissions. BURR-BROWN assumes
no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change
without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. BURR-BROWN does not authorize or warrant
any BURR-BROWN product for use in life support devices and/or systems.
®
11 ISC300

11 Page







PáginasTotal 11 Páginas
PDF Descargar[ Datasheet ISC300.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
ISC300Universal Precision Isolated MEASUREMENT CHANNELBurr-Brown Corporation
Burr-Brown Corporation

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar