DataSheet.es    


PDF AS2000T Data sheet ( Hoja de datos )

Número de pieza AS2000T
Descripción Thermostatic and Manual Power Shower
Fabricantes Triton 
Logotipo Triton Logotipo



Hay una vista previa y un enlace de descarga de AS2000T (archivo pdf) en la parte inferior de esta página.


Total 28 Páginas

No Preview Available ! AS2000T Hoja de datos, Descripción, Manual

.
tAhqeurmasoesntsaatitcioanndASm2a0n0u0aTl
/ AS2000
power shower
.
ww.DataSheet4U.comInstallation
wINSTALLERS PLEASE NOTE
TaHnESEd2IN1O8S0T2Rp3U7CeE TJrIuOanN9tS9iAnREgTOInBEwsLtwErFwuT.WDcatITtiHaoSTnHhEesUeStE4RU.com

1 page




AS2000T pdf
AQUASENSATION AS2000T / AS2000
KEY TO MAIN COMPONENTS
1 Top pipe entry and cable entry
2 Terminal block
3 Cable clamp
4 Cover screw fixing
5 Motor cover
6 Rear pipe entry and cable entry
7 Wall fixing holes
8 Pipe inlet elbow - top
(contains single check valves)
9 Filter cover - top
10 Pump
11 PCB housing
12 Setting adaptor
13 Temperature control valve
14 Solenoid
15 Filter cover - bottom
16 Pipe inlet elbow - bottom
(contains single check valves)
17 Outlet
18 Bottom pipe entry
1
4
2
5
6
7
DISCONNECT FROM
ELECTRICITY SUPPLY
BEFORE REMOVING
THIS COVER
8
9
Fig.1
86
mm
3
7
268
mm
10
12
11
14
7
15
7
13
16
4
17
206 mm
18 56 mm
82 mm
SPECIFICATIONS
Hot water temperature
Maximum temperature 80°C.
BS6700 recommends that the temperature of
stored water should never exceed 65°C. A stored
water temperature of 60°C is considered sufficient
to meet all normal requirements and will minimise
the affects of scale in hard water areas.
Temperature control (Thermostatic only)
To obtain the maximum performance, this unit
should be installed, operated and maintained as
instructed in this book. The full performance
specification as below for the standard unit is
achieved with a blend set between 35°C – 40°C
and supplies of 15°C cold and 65°C hot with
nominally equal pressures.
1) The blended water temperature is maintained
within 2°C with a 10°C change in the hot and
cold water supply.
2) The sensor effects a shut down to seepage in
approximately 2 seconds if the cold supply fails.
3) Shut down to seepage is achieved even if the
hot supply is only 12°C above the blend
temperature.
4) The blended water temperature is maintained
within 1°C when the pressure between inlet and
outlet is halved (defined as a pressure loss ratio of
2:1) on either the hot or cold side.
Maximum static inlet pressures
1 bar or 10m (supplies must be gravity fed at
nominally equal pressures).
Minimum static inlet pressure
0.0075 bar or 75mm (required to prime the
integral centrifugal pump).
3

5 Page





AS2000T arduino
AQUASENSATION AS2000T / AS2000
tube. The fittings can be used with copper
and plastic pipe.
If using chrome plated copper pipe, remove
the first 25mm of plating completely from
the connecting surfaces. If not completely
removed then the collet will not grip the
pipe and under pressure the pipe may be
forced out
NOTE: Pipework must be clipped or fixed to
the wall so that it cannot be moved or
removed without the aid of a tool.
NOTE: The pipe inlets contain filters. These
should be periodically removed and cleaned
in order to maintain the performance of the
shower. See section ‘cleaning’ on how to
access the filters.
Important: The inlets contain check valves,
so before completing the connection of the
water supplies to the shower flush out the
pipework to remove all swarf and system
debris that may cause damage to internal
parts. This can be achieved by connecting a
hose to the pipework and turning on the
water supplies long enough to clear the
debris to waste (Byelaw 55).
Two factory fitted blanking plugs are fitted
to the top pipe inlets. These should be left in
position if bottom pipe entry is required. But
for top or rear pipe entry, the two plugs
must be removed and re-fitted into the
bottom pipe inlets.
Insert the pipe removal tool supplied
between the flange of the plug and the grey
collet and lever the plug outward (fig.13).
Whilst holding back on the collet, pull out
each plug by hand. When re-fitting the plugs
in the bottom pipe inlets, ensure they are
pushed fully home.
Hot
side
Top
(falling)
or rear
supply
Fig.11
Bottom
(rising)
supply
Fig.12
Hot
side
Fig.13
Blanking
plug
9

11 Page







PáginasTotal 28 Páginas
PDF Descargar[ Datasheet AS2000T.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
AS2000TThermostatic and Manual Power ShowerTriton
Triton

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar