IPN =
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
5 .. 10 A
Electrical data
Primary nominal
r.m.s. current
IPN (A)
Series
Parallel
±5
± 10
± 10
± 20
Primary current
measuring range
IP (A)
Series
Parallel
± 15 ± 30
± 30 ± 60
Primary Conductor
Diameter x Turns
(mm)
0.7d x (6T+6T)
1.0d x (3T+3T)
Type
HX 05-NP
HX 10-NP
VOUT
Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C
±4
V
ROUT
Output impedance
< 50
Ω
R L Load resistance
≥ 10
kΩ
VC Supply voltage (± 5 %)1)
± 15
V
I C Current consumption
< ± 20
mA
Vd
R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn
Primary to secondary
>3
kV
Primary 1 to primary 2
> 1 kV
Ve R.m.s. voltage for partial discharge extinction
at 10pC
≥ 1 kV
Impulse withstand voltage, 1.2/50µs
≥ 6 kV
Accuracy-Dynamic performance data
X
εL
VOE
VOH
εVOT
TC G
tr
f
Accuracy @ IPN, TA = 25°C (without offset)
Linearity (0 .. ± IPN)
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @
after an excursion of 3 x IPN
IP =
0;
Thermal drift of VOE
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
Frequency bandwidth (-3 dB) 2)
<±1
<±1
< ± 40
< ± 15
max. ± 1.5
± 0.1
≤3
50
% of IPN
% of IPN
mV
mV
mV/K
%/K
µs
kHz
General data
TA Ambient operating temperature
TS
m
Ambient storage temperature
Mass
- 25 .. + 85 °C
- 25 .. + 85 °C
8g
Min. internal creepage distance/clearance
≥ 5.5
mm
Isolation material group
I
Standards
EN50178
Notes :1) Also operate at ±12V power supplies, measuring range reduced to ±2.5x IPN
2) Small signal only to avoid excessive heating of the magnetic core
Features
• Galvanic isolation between primary
and secondary circuit
• Hall effect measuring principle
• 2 isolated primary windings
• Isolation voltage 3000V
• Low power consumption
• Extended measuring range(3x IPN)
• Power supply from ±12V to ±15V
• Material according to UL94-V0
Advantages
• Low insection losses
• Easy to mount with automatic
handling system
• Small size and space saving
• High immunity to external
interference.
Applications
• Switched Mode Power Supplies
(SMPS)
• AC variable speed drives
• Uninterruptible Power Supplies
(UPS)
• Electrical appliances
• Battery supplied applications
• DC motor drives
LEM Components
011012/2
www.lem.com
1 page |
Páginas | Total 2 Páginas | |
PDF Descargar | [ Datasheet HX05-NP.PDF ] |
Número de pieza | Descripción | Fabricantes |
HX05-NP | Current Transducer HX 05~10-NP | LEM |
Número de pieza | Descripción | Fabricantes |
SLA6805M | High Voltage 3 phase Motor Driver IC. |
Sanken |
SDC1742 | 12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters. |
Analog Devices |
DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares, |
DataSheet.es | 2020 | Privacy Policy | Contacto | Buscar |