DataSheet.es    


PDF PM4H-S Data sheet ( Hoja de datos )

Número de pieza PM4H-S
Descripción MULTI-RANGE ANALOG TIMER
Fabricantes NAiS 
Logotipo NAiS Logotipo



Hay una vista previa y un enlace de descarga de PM4H-S (archivo pdf) en la parte inferior de esta página.


Total 29 Páginas

No Preview Available ! PM4H-S Hoja de datos, Descripción, Manual

DIN48 SIZE
MULTI-RANGE ANALOG TIMER
PM4H-A
PM4H-S
PM4H-M
FEATURES
Front panel of IP65 type is protected against water-splash and dust
100-240V AC free-voltage input
48 Built-in Screw terminals
1.89 Screw terminal type is used for easy wiring and reducing additional cost for
accessories.
8 different operation modes: (PM4H-A)
48
62.5 mm inch Tube base with pin style terminals
2.46
1.89 Multiple time ranges — 1 s to 500 h (Max.)
Short body — 62.5mm 2.46 inch (screw terminal type)
Socket
mount
Flush mount
PRODUCT TYPE
Type
Operation mode
Contact
arrangement
Time range
Protective
construction
Rated
operating voltage
Terminal type
Part No.
100 to 240V AC
11 pin
PM4HA-H-AC240VW
Screw terminal PM4HA-H-AC240VSW
PM4H-A
8 operation modes
Pulse ON-delay
Pulse Flicker
Pulse ON-flicker
Differential ON/OFF-delay (1) (2)
Signal OFF-delay
Pulse One-shot
Pulse One-cycle
Relay
Timed-out
2 Form C
IP65
IP50
24V AC/DC
12V DC
100 to 240V AC
24V AC/DC
11 pin
Screw terminal
11 pin
Screw terminal
11 pin
Screw terminal
11 pin
Screw terminal
PM4HA-H-24VW
PM4HA-H-24VSW
PM4HA-H-DC12VW
PM4HA-H-DC12VSW
PM4HA-H-AC240V
PM4HA-H-AC240VS
PM4HA-H-24V
PM4HA-H-24VS
12V DC
11 pin
PM4HA-H-DC12V
Screw terminal PM4HA-H-DC12VS
100 to 240V AC
8 pin
PM4HS-H-AC240VW
Screw terminal PM4HS-H-AC240VSW
IP65
24V AC/DC
8 pin
PM4HS-H-24VW
Screw terminal PM4HS-H-24VSW
PM4H-S Power ON-delay
Relay
Timed-out
2 Form C
16 selectable
ranges
1s to 500h
12V DC
100 to 240V AC
8 pin
Screw terminal
8 pin
Screw terminal
PM4HS-H-DC12VW
PM4HS-H-DC12VSW
PM4HS-H-AC240V
PM4HS-H-AC240VS
IP50
24V AC/DC
8 pin
PM4HS-H-24V
Screw terminal PM4HS-H-24VS
12V DC
8 pin
PM4HS-H-DC12V
Screw terminal PM4HS-H-DC12VS
100 to 240V AC
8 pin
PM4HM-H-AC240VW
Screw terminal PM4HM-H-AC240VSW
PM4H-M
5 operation modes
(With instantaneous contact)
Power ON-delay
Power Flicker
Power ON-flicker
Power One-shot
Power One-cycle
Relay
Timed-out
1 Form C
Instantaneous
1 Form C
IP65
IP50
24V AC/DC
12V DC
100 to 240V AC
24V AC/DC
8 pin
Screw terminal
8 pin
Screw terminal
8 pin
Screw terminal
8 pin
Screw terminal
PM4HM-H-24VW
PM4HM-H-24VSW
PM4HM-H-DC12VW
PM4HM-H-DC12VSW
PM4HM-H-AC240V
PM4HM-H-AC240VS
PM4HM-H-24V
PM4HM-H-24VS
12V DC
8 pin
PM4HM-H-DC12V
Screw terminal PM4HM-H-DC12VS
If you use this timer under harsh environment, please order above sealed type (IP65 type). IP65 type — Protection dust and water jet splay on the front face.
TIME RANGE
Time unit
Scale
sec
min
1
0.1s to 1s
0.1 min to 1 min
5 Control
0.5s to 5s
0.5 min to 5 min
10
time range
1.0s to 10s
1.0 min to 10 min
50
5s to 50s
5 min to 50 min
Note: 0 setting is for instantaneous output operation.
30
hrs
0.1h to 1h
0.5h to 5h
1.0h to 10h
5h to 50h
10h
1.0h to 10h
5h to 50h
10h to 100h
50h to 500h
PM4H-A/PM4H-S/PM4H-M
All types of PM4H timer have multi-time
range.
16 time ranges are selectable.
1s to 500h (Max. range) is controlled.

1 page




PM4H-S pdf
Operation mode
Pulse
One-shot
OS
Operation
Turn the operation selector to OS .
Power is applied continuously. When a start signal is applied, the
output contacts change state immediately and time cycle begins.
When the time delay is completed, the output contacts return to their
normal state. The contacts will return to normal state when a reset
signal is applied or power is removed.
(Note: When a stop signal is applied during timing operation, the
time cycle stops. When a stop signal is removed, the time cycle
resumes where it left off.)
Differential
ON/OFF-delay (2)
OF2
Pulse
One-cycle
OC
Turn the operation selector to OF2 .
Power is applied continuously.
When a start signal is applied, the ON-delay time cycle begins and
the output contacts remain in their normal state. The output contacts
change state after time delay is completed. When the start signal is
removed the OFF-delay time cycle begins. The output contacts
return to their normal state after the time delay is completed. If the
start signal is applied or removed during the timing operation, the
output contacts will change state and the time cycle starts over.
The contacts will return to their normal state when a reset signal is
applied or power is removed.
(Note: When a stop signal is applied during timing operation, the
time cycle stops. When a stop signal is removed, the time cycle
resumes where it left off.)
Turn the operation selector to OC .
Power is applied continuously.
When a start signal is applied, the time cycle begins but the output
contacts remain in their normal state. The output contacts change
state for 0.8s after time delay is completed.
Reset will occur when a reset signal is applied or power is removed.
(Note: When a stop signal is applied during timing operation, the
time cycle stops. When a stop signal is removed, the time cycle
resumes where it left off.)
Note: Keep 0.1s or more for power off time.
Keep 0.05s or more for signal, stop, reset input time.
Time chart
Power supply
ON
Operation signal
ON
OFF
ON
Reset
Stop
Time out (N.O. contact)
T
ON
T
OFF
ON
OFF
t1 t2
OFF
ON
OFF
ta
OFF
OP. LED
POWER LED
Note:
LED lighting or No LED lighting
Power supply
ON
OFF
Operation signal
ON
OFF
ON
OFF
Reset
ON
OFF
Stop
ON
OFF
T
t1 t2
ta tb
Time out (N.O. contact)
ON
OFF
ON
OFF
OP. LED
POWER LED
Restart
Note: LED lighting or No LED lighting
Power supply
ON
OFF
Operation signal
ON
OFF
ON
OFF
ON
OFF
Reset
ON
OFF
ON
OFF
Stop
ON
OFF
Tt
T
t1
t2 t
ta
Time out (N.O. contact)
ON
OFF
ON
OFF
OP. LED
POWER LED
One pulse time (t): Approx. 0.8s
Note: LED lighting or No LED lighting
PM4H-S
Operation mode
Operation
When power is applied continuously, the time cycle begins. The out-
put contacts change state after the time delay is completed.
Power ON-delay
Power supply
Time out (N.O. contact)
OP. LED
POWER LED
LED lighting
T: Setting time
Time chart
LED flickering
ON
ON
T
OFF
OFF
PM4H-M
Operation mode
Operation
Time chart
Power ON-delay
ON
Power Flicker
FL
Power ON-flicker
FO
Power One-shot
OS
Power One-cycle
OC
Power ON-delay
When power is applied continuously, the instantaneous output con-
tact changes state and the timing cycle begins. The timed contact
changes state after the time delay is completed.
Reset will occur when power is removed.
PM4H-M timers do not have external signal, reset and stop inputs.
(For other operation modes, refer to the operation mode of PM4H-A.)
Power ON-delay
Power supply
ON
Time out (N.O. contact)
Instantaneous contact (N.O. contact)
T
ON
OP. LED
POWER LED
ON
Note: Keep 0.1s or more for power off time. PM4H-M timers do not have each input which is signal, reset and stop.
34
OFF
OFF
OFF

5 Page





PM4H-S arduino
WIRING DIAGRAMS
PM4H-F8 (no reset input)
Pin type
Time-delay 2C
N.C.
N.O.
N.C.
N.O.
COM
COM
(–) Operating (+)
voltage
PM4H-F8R (with reset input)
Pin type
Time-delay 1C, with reset input
Reset input
N.C.
N.O.
COM
(–) Operating (+)
voltage
PM4H-F11R (with reset input)
Pin type
Time-delay 2C, with reset input
Reset input
N.O. N.C.
N.C.
N.O.
COM
(–) Operating (+)
voltage
COM
Screw terminal type
Time-delay 2C, with reset input
COM
COM
N.O. N.C.
(+)
Operating
voltage
(–)
N.C. N.O.
Reset input
PM4H-F (WITH RESET) INPUT CONDITIONS
1. Contact operating input (pin type example)
2. Non-contact input (pin type example)
PM4H-F8R PM4H-F11R
Reset input
Reset input
Use a contact with good contact relia-
bility for the input. Contact bounce
can lead to erroneous operation of
the timer, so use a contact with short
bounce time. Make the resistance
between terminals for a short circuit
less than 1k-ohms. Make the resis-
tance between terminals for an open
circuit greater than 100k-ohms.
PM4H-F8R
Reset input
Photo-coupler
PM4H-F11R
Photo-coupler
Reset input
Be sure to use a photo-
coupler for non-contact
input.
Check that Vce = 0.6V
Max. when ON.
TIME RANGE
Time range
Time range unit
1
5
10
second range
0.04s to 1s
0.2s to 5s
0.4s to 10s
minute range
0.04 min to 1 min
0.2 min to 5 min
0.4 min to 10 min
40

11 Page







PáginasTotal 29 Páginas
PDF Descargar[ Datasheet PM4H-S.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
PM4H-AMULTI-RANGE ANALOG TIMERNAiS
NAiS
PM4H-MMULTI-RANGE ANALOG TIMERNAiS
NAiS
PM4H-SMULTI-RANGE ANALOG TIMERNAiS
NAiS

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar